Aluminium Conductor Alloy Reinforced (ACAR) is formed by concentrically stranded wires of Aluminium on high strength Aluminium -Magnesium -Silicon(Al Mg Si) alloy core.

Application

IEC 61089 covers round wire concentric lay overhead electrical stranded conductors—specifically AAC, AAAC, ACSR, and ACAR,used for overhead power transmission and distribution lines.

Standard

IEC 61089

Construction

Aluminium Conductor Alloy Reinforced (ACAR) is formed by concentrically stranded wires of Aluminium on high strength Aluminium alloy core.

Technical data

ACAR/A1/A2

Code
Number
DiameterNo.of
Wires
AreasLinear MassRated
Strength
D.C.
Resistance
WireCondA1A2A1A2Total
mmmmNo.No.mm²mm²mm²kg/kmkNΩ/km
161.765.28439.737.3017.046.63.851.7896
252.206.604315.211.426.672.85.931.1453
402.788.354324.318.342.6116.59.250.7158
633.4910.54338.328.767.1183.514.380.4545
1004.4013.24360.845.6106291.222.520.2863
1252.9714.912783.348.6132362.727.790.2302
1603.3616.812710762.2169464.235.040.1798
2003.7618.812713377.8211580.343.130.1439
2504.2121.012716797.2264725.353.920.1151
2503.0421.31819131138269742.260.390.1154
3153.3423.430726361.3324892.660.520.0916
3153.4223.91819165174339935.176.090.0916
4003.7626.330733477.84111133.575.190.0721
4003.8527.018192102214311187.595.580.0721
4503.9927.930737587.64631275.284.590.0641
4504.0828.618192362494851335.9107.520.0641
5004.2129.430741797.35141416.993.980.0577
5004.3130.118192622775391484.3119.470.0577
5604.4531.23074671095761586.9105.260.0515
5603.4531.054750465.45701571.9101.540.0516
6303.7133.442194542056601820.0130.250.0458
6303.7934.124372714176881897.5160.190.0458
7103.9435.542195122327432051.2146.780.0407
7104.0236.224373054707752138.4180.530.0407
8004.1837.642195772618382311.2165.390.0361
8004.2738.424373445308732409.5203.410.0361
9004.4339.942196492949422600.1186.060.0321
9003.6640.254375673889552638.4199.540.0321
10003.8041.8721981621510322849.1190.940.0289
10003.8542.4543763043210612931.6221.710.0289
11204.0244.2721991424111553191.0213.850.0258
11204.0844.9543770548311893283.4248.320.0258
12504.2546.77219102026912893561.4238.680.0231
12504.3147.4543778753913273664.5277.140.0231
14004.5049.47219114330214443988.8267.320.0207

ACAR/A1/A3

Code
Number
DiameterNo.of
wires
AreasLinear massRated
strength
D.C.
resistance
WireCondA1A2A1A2Total
mmmm  mm²mm²mm²kg/kmkNΩ/km
161.765.29439.787.3317.146.84.071.7896
252.216.624315.311.526.773.16.291.1453
402.798.374324.418.342.8117.09.820.7158
633.5010.54338.528.967.4184.314.800.4545
1004.4113.24361.145.8107292.523.490.2863
1252.9814.912783.748.8132364.129.290.2302
1603.3716.912710762.5170466.036.950.1798
2003.7718.812713478.1212582.544.780.1439
2504.2121.112716797.6265728.155.980.1151
2503.0521.41819132139271746.064.670.1154
3153.3423.430726361.4325894.462.400.0916
3153.4324.01819166175341940.081.480.0916
4003.7726.430733478.04121135.876.820.0721
4003.8627.018192112224331193.7100.300.0721
4503.9928.030737687.74641277.886.420.0641
4504.1028.718192372504871342.9112.840.0641
5004.2129.530741897.55151419.896.030.0577
5004.3230.218192632785421492.1125.380.0577
5604.4631.23074681095771590.1107.550.0515
5603.4531.154750565.55701573.9103.530.0516
6303.7233.442194562066621826.0134.590.0458
6303.8034.224372724206921909.0169.140.0458
7103.9535.542195142327462057.8151.680.0407
7104.0336.324373074737802151.4190.610.0407
8004.1937.742195792628402318.7170.900.0361
8004.2838.524373465338792424.2214.780.0361
9004.4440.042196512949452608.5192.270.0321
9003.6640.354375693909592649.5207.790.0321
10003.8041.8721981821610342855.4195.470.0289
10003.8642.5543763243310662943.9230.880.0289
11204.0244.3721991624211583198.1218.920.0258
11204.0945.0543770848511943297.2258.580.0258
12504.2546.87219102227012923569.3244.330.0231
12504.3247.5543779154213323679.9288.600.0231
14004.5049.57219114530214473997.6273.650.0207

FAQ

What is bare ACAR conductor?

ACAR stands for Aluminium Conductor Alloy Reinforced. It is a stranded bare overhead conductor using aluminium alloy strands as the reinforcing core instead of steel, combined with conductive aluminium wires.

Does IEC 61089 cover bare ACAR conductors?

Yes. IEC 61089 applies to all round wire bare overhead conductors, including ACAR, AAC and ACSR. It sets unified requirements on dimensions, performances and test rules for ACAR.

Is ACAR suitable for coastal and corrosive environments?

Yes. Compared with conventional ACSR, ACAR has excellent anti-corrosion performance, making it a preferred choice for coastal, industrial and humid corrosive areas.

Get In Touch

Let’s Build Something
Together.

No. 238, Zhenkang Road, Zhangyan Town,Jinshan District, Shanghai,China

Quick Link

Learn More About Us

About QIFAN
About QIFAN
We are a leading cable manufacturer in China with over 30 years of experience.
Customer Service
Customer Service
Exceptional Service– From First Contact to Long-Term Partnership
Quality Assurance
Quality Assurance
Advanced imported production lines; ISO 9001/14001/OHSAS 18001, TUV, VDE, UL, CE, SAA certified.