Home | Products | Cables by Standard | ICEA S-93-639 Cable | 8KV 133% XLPE INSULATION PVC 1/0AWG POWER CABLE

ICEA S-93-639 Cable, Medium Voltage Cable, Building Cable

8KV 133% XLPE INSULATION PVC 1/0AWG POWER CABLE

Designed for excellence in functionality, this product is ideal for power transmission and distribution, effortlessly handling rated power frequency voltages from an impressive range of 5kv to 46kv.

  • Standard: ICEA S-93-639
  • Certificate: ISO 9001. ISO 14001. ISO 45001
  • UV Proof, Flame Retardant

 

 

Application

Designed for excellence in functionality, this product is ideal for power transmission and distribution, effortlessly handling rated power frequency voltages from an impressive range of 5kv to 46kv.

Characteristics

  • Voltage Rating: 8kV
  • Max. conductor temperature in service 90 °C
  • Max. Short time overload temperature(2 h)130 °C
  • Maximum conductor short time temperature 250 °C
  • Bending factor when laying

Products Construction

• Conductor: Stranded Compacted Copper or Aluminium Wire , Class B Conductor

• Conductor Shield : Semi-conductor XLPE Compound

• Insulation: 133% XLPE

• Insulation Shield: Semi-conductor XLPE Compound

• Metallic screen: Copper tape

• Wrapping tape(optional): Non-woven clothing tape

• Outer sheath : PVC

Applicable Standards

ICEA S-93-639

Optional

Conductor can be water blocking
Anti-termite
Anti-rodent
Oil Resistance
UV Resistance
Low Smoke Zero Halogen

Technical Parameters

Phase ConductorNeutralThickness Per Cond. (mils)Diameter (mils)Weight 1000 feet (lbs.)
Size (AWG or kcmil)StrandingNo. of WiresSize (AWG)Nominal Insul.Insul. Shield min. PointApprox. Jkt.Bare Phase Cond.Over Insul.Over Insul. ShieldComp. CableComp. Cable
ALUMINUM CONDUCTOR – 0.345 INSULATION – 100% INSULATION LEVEL ” FULL COPPER WIRE NEUTRAL
1*1/01916143454055335106611761414977
1*2/019131234540553761107121714881123
1*3/019161234540554231153126315341249
1*4/019131034540804741212132216861537
1*25037151034540805231261137117351678
1*30037181034540805721310142017841858
1*35037211034540806171355146518292034
1*4003719934540806611399150918982243
1*4503721934540807011439154919382400
1*5003719834540807381476158620032626
1*5506121834555807831527165720742859
1*6006123834555808171561169121083033
1*6506125834555808501594172421413205
1*7006126834555808831627175721743332
1*7506128834555809141658178822053502
1*8006130834555809431687181722343671
ALUMINUM CONDUCTOR – 0.345 INSULATION – 100% INSULATION LEVEL ” 1/3 COPPER WIRE NEUTRAL
1*1/0196143454055335106611761414859
1*2/0197143454055376110712171455928
1*3/01991434540554231153126315011021
1*4/019111434540554741212132215611136
1*25037131434540555231261137116091237
1*30037151434540805721310142017081405
1*35037181434540806171355146517541525
1*40037131234540806611399150918311682
1*45037141234540807011439154918701780
1*50037161234540807381476158619071896
1*55061181234555807831527165719792067
1*60061191234555808171561169120132163
1*65061131034555808501594172420882333
1*70061141034555808831627175721212440
1*75061151034555809141658178821522545
1*80061161034555809431687181721812648
1*900611810345558010011745187522392854
1*1000612010345558010551800193022933058
1*125061209345558011801924205424433606
Phase ConductorNeutralThickness Per Cond. (mils)Diameter (mils)Weight 1000 feet (lbs.)
Size (AWG or kcmil)StrandingNo. of WiresSize (AWG)Nominal Insul.Insul. Shield min. PointApprox. Jkt.Bare Phase Cond.Over Insul.Over Insul. ShieldComp. CableComp. Cable
ALUMINUM CONDUCTOR – 0.345 INSULATION – 100% INSULATION LEVEL ” 1/6 COPPER WIRE NEUTRAL
1*1/0195163454055335106611761387799
1*2/0196163454055376110712171428863
1*3/0197163454055423115312631475938
1*4/01991634540554741212132215341044
1*25037101634540555231261137115831128
1*3003781434540805721310142017081323
1*3503791434540806171355146517541418
1*40037101434540806611399150917971515
1*45037121434540807011439154918371617
1*5003781234540807381476158619071746
1*5506191234555807831527165719791899
1*60061101234555808171561169120131995
1*65061111234555808501594172420462089
1*70061111234555808831627175720792166
1*75061121234555809141658178821092258
1*80061131234555809431687181721392349
1*900611412345558010011745187521962513
1*1000611612345558010551800193022512693
1*1250612012345558011801924205423763112

FAQ

What is concentric cable used for?

Concentric cables are primarily used by utility companies and electricians to connect the main power grid to residential properties and buildings. Their unique design surrounds the central “live” conductor with the neutral and earth wires, preventing tampering and offering superior protection against accidental damage and shock.

What is the difference between MV 105 and mv90?

MV-90 and MV-105 are classifications for medium-voltage (MV) power cables, where the numbers designate their maximum continuous conductor operating temperatures:
and respectively.

Why use concentric neutral cable?

Concentric neutral cables use a central phase conductor wrapped in a layer of bare wires that act as the neutral. They are widely used for underground power distribution and service entrances because they provide an excellent ground fault return path, balance electrical stresses, and shield the center conductor for safety

What does concentric mean in electrical terms?

At its heart, a concentric cable is an electrical cable defined by its unique, layered construction. Think of it like the rings of a tree trunk. It features a central “live” or “phase” conductor that is wrapped in a layer of high-grade insulation.

What is the difference between concentric neutral and shielded cable?

What’s the difference between a concentric neutral and a tape shield on MV cable? A concentric neutral consists of spiraled bare copper strands designed to carry ground fault current, while a tape shield is a flat copper or aluminum tape for electrostatic shielding only. They require different grounding practices.

Can I connect neutral and ground together?

No, you can only tie the neutral and ground wires together at your main service panel (where your utility power enters the building). Connecting them anywhere else (like in an outlet, light switch box, or subpanel) is an electrical code violation and creates severe shock and fire hazards.

Get In Touch

Let’s Build Something
Together.

No. 238, Zhenkang Road, Zhangyan Town,Jinshan District, Shanghai,China

Quick Link

Learn More About Us

About QIFAN
About QIFAN
We are a leading cable manufacturer in China with over 30 years of experience.
Customer Service
Customer Service
Exceptional Service– From First Contact to Long-Term Partnership
Quality Assurance
Quality Assurance
Advanced imported production lines; ISO 9001/14001/OHSAS 18001, TUV, VDE, UL, CE, SAA certified.