Home | Products | Cables by Industry | Building Cable | NYBY Cable 0.6/1kV

Low Voltage Cable, IEC 60502 Cable, Building Cable

NYBY Cable 0.6/1kV

These power cables are used for electricity supply in low voltage installation systems. They are well adapted to underground use in industrial applications with an additional mechanical protection. Able to bear external mechanical force, but unable to bear large pulling force.

  • Certificates: ISO 9001 ISO14001 ISO 45001
  • Standard:  IEC 60502-1
  • Characteristics: anti-termite / anti-vermin and Flame-retardant/UV Resistant

NYBY 0.6/1kV Multicore armored cable
Multicore PVC insulated PVC sheathed armored cable with copper conductor

CU-XLPE-PVC-STA-PVC

Application:

To be used for main power supply, In low voltage distribution power networks, industrial installations, in buildings and operation stations. fixed installation in the ground or in concrete, in the cable trenches or cable, ducts, indoor or outdoor areas, in dry or wet locations.

Standard:

  • Cable design: IEC 60502-1
  • Conductor: IEC 60228

Construction

  • 1.    Conductor – Plain annealed class 2 stranded (compacted) copper
  • 2.    Insulation – Cross-linked polyethylene (XLPE)
  • 3.    Filler – Non-hygroscopic material
  • 4.    Binder tape – Non-hygroscopic material tape
  • 5.  Inner sheath – Polyvinyl chloride compound (PVC)
  • 6.  Armor – Galvanized steel tape
  • 7.    Outer sheath – Polyvinyl chloride compound (PVC)

Cross Section:

  • 2C1.5~2C400mm2
  • 3C1.5~3C400mm2
  • 4C1.5~4C400mm2
  • 5C1.5~5C400mm2
  • 2C+E2.5~2C+E400mm2
  • 3C+E2.5~3C+E400mm2
  • 4C+E2.5~4C+E400mm2

Temperature characteristics:

  • Conductor operating temperature: -15℃~90℃                  
  • Min. temperatrue laying condition: 0℃                 
  • Conductor short-circuit operating temperature (5s): 250℃

Electrical Characteristics:

  • Rated voltage: 0.6/1 (1.2) kV
  • High voltage test: 3.5kV / 5min

Color:

  • Insulation: According to customer requirements
  • Outer sheath: Black or according to customer requirements

Minimum Bending Radius

ItemsSingle-core CablesThree-core Cables
UnarmouredArmouredUnarmouredArmoured
Min. bending radius during installation20D15D15D12D
Min. bending radius close to connection box and termination (bending radius should be controlled carefully, if the molding guide plate is used)15D12D12D10D

Applicable Standards

IEC 60502-1

Optional

anti-termite / anti-vermin
Flame-retardant
UV Resistance

Technical Parameters

Two cores
Three core
Four cores
Five cores
3+1Cores
3+2Cores
4+1Cores
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
2×1.5 1 0.8 0.2 1.8 12.6 236 12.1
2×2.5 1 0.8 0.2 1.8 13.4 274 7.41
2×4 1 1 0.2 1.8 15.2 354 4.61
2×6 1 1 0.2 1.8 16.2 419 3.08
2×10 6 1 0.2 1.8 18.7 566 1.83
2×16 6 1 0.2 1.8 20.3 721 1.15
2×25 6 1.2 0.2 1.8 23.5 991 0.727
2×35 6 1.2 0.2 1.8 25.5 1229 0.524
2×50 6 1.4 0.2 1.8 28.9 1580 0.387
2×70 12 1.4 0.2 1.9 32.8 2094 0.268
2×95 15 1.6 0.5 2.1 38.8 3144 0.193
2×120 18 1.6 0.5 2.2 41.8 3743 0.153
2×150 18 1.8 0.5 2.4 46.4 4545 0.124
2×185 30 2 0.5 2.5 50.6 5493 0.0991
2×240 34 2.2 0.5 2.7 56.4 6894 0.0754
2×300 34 2.4 0.5 2.9 62.4 8467 0.0601
2×400 53 2.6 0.5 3.1 69.2 10547 0.047
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
3×1.5 1 0.8 0.2 1.8 13.1 266 12.1
3×2.5 1 0.8 0.2 1.8 14 314 7.41
3×4 1 1 0.2 1.8 15.8 415 4.61
3×6 1 1 0.2 1.8 16.9 502 3.08
3×10 6 1 0.2 1.8 19.7 692 1.83
3×16 6 1 0.2 1.8 21.4 905 1.15
3×25 6 1.2 0.2 1.8 24.8 1267 0.727
3X35 6 1.2 0.2 1.8 27 1597 0.524
3×50 6 1.4 0.2 1.9 30.9 2087 0.387
3×70 12 1.4 0.2 2 35 2804 0.268
3×95 15 1.6 0.5 2.2 41.4 4140 0.193
3×120 18 1.6 0.5 2.3 44.6 4971 0.153
3×150 18 1.8 0.5 2.5 49.5 6054 0.124
3×185 30 2 0.5 2.6 54 7371 0.0991
3×240 34 2.2 0.5 2.8 60.6 9380 0.0754
3×300 34 2.4 0.5 3 66.7 11484 0.0601
3×400 53 2.6 0.5 3.3 74.6 14504 0.047
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
4×1.5 1 0.8 0.2 1.8 13.9 304 12.1
4×2.5 1 0.8 0.2 1.8 14.8 364 7.41
4×4 1 1 0.2 1.8 16.9 489 4.61
4×6 1 1 0.2 1.8 18.2 600 3.08
4×10 6 1 0.2 1.8 21.2 839 1.83
4×16 6 1 0.2 1.8 23.2 1113 1.15
4×25 6 1.2 0.2 1.8 27 1578 0.727
4×35 6 1.2 0.2 1.9 29.6 2019 0.524
4×50 6 1.4 0.2 2 34.7 2698 0.387
4×70 12 1.4 0.5 2.2 39.9 3966 0.268
4×95 15 1.6 0.5 2.4 46 5295 0.193
4×120 18 1.6 0.5 2.5 49.6 6377 0.153
4×150 18 1.8 0.5 2.6 54.4 7694 0.124
4×185 30 2 0.5 2.8 60 9495 0.0991
4×240 34 2.2 0.5 3 67 12027 0.0754
4×300 34 2.4 0.5 3.2 74.1 14840 0.0601
4×400 53 2.6 0.5 3.5 82.4 18673 0.047
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
5×1.5 1 0.8 0.2 1.8 14.7 344 12.1
5×2.5 1 0.8 0.2 1.8 15.8 417 7.41
5×4 1 1 0.2 1.8 18.1 567 4.61
5×6 1 1 0.2 1.8 19.5 702 3.08
5×10 6 1 0.2 1.8 22.9 992 1.83
5×16 6 1 0.2 1.8 25.1 1330 1.15
5×25 6 1.2 0.2 1.9 29.6 1913 0.727
5×35 6 1.2 0.2 1.9 33 2489 0.524
5×50 6 1.4 0.5 2.2 39.4 3670 0.387
5×70 12 1.4 0.5 2.3 43.6 4799 0.268
5×95 15 1.6 0.5 2.5 50.4 6424 0.193
5×120 18 1.6 0.5 2.6 54.3 7758 0.153
5×150 18 1.8 0.5 2.8 60.3 9472 0.124
5×185 30 2 0.5 3 66.1 11621 0.0991
5×240 34 2.2 0.5 3.2 74.2 14827 0.0754
5×300 34 2.4 0.5 3.5 81.8 18251 0.0601
5×400 53 2.6 0.8 3.8 92.2 23887 0.047
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
3×2.5+1×1.5 1/1 0.8/0.8 0.2 1.8 14.6 349 7.41/12.1
3×4+1×2.5 1/1 1.0/0.8 0.2 1.8 16.4 457 4.61/7.41
3×6+1×4 1/1 1.0/1.0 0.2 1.8 17.9 572 3.08/4.61
3×10+1×6 6/1 1.0/1.0 0.2 1.8 20.5 778 1.83/3.08
3×16+1×10 6/6 1.0/1.0 0.2 1.8 22.7 1044 1.15/1.83
3×25+1×16 6/6 1.2/1.0 0.2 1.8 26.1 1459 0.727/1.15
3×35+1×16 6/6 1.2/1.0 0.2 1.8 27.9 1778 0.524/1.15
3×50+1×25 6/6 1.4/1.2 0.2 1.9 32.8 2416 0.387/0.727
3×70+1×35 12/6 1.4/1.2 0.2 2.1 36.6 3196 0.268/0.524
3×95+1×50 15/6 1.6/1.4 0.5 2.3 43.2 4683 0.193/0.387
3×120+1×70 18/12 1.6/1.4 0.5 2.4 47.2 5771 0.153/0.268
3×150+1×70 18/12 1.8/1.4 0.5 2.5 50.9 6755 0.124/0.268
3×185+1×95 30/15 2.0/1.6 0.5 2.7 56.2 8381 0.0991/0.193
3×240+1×120 34/18 2.2/1.6 0.5 2.9 62.8 10611 0.0754/0.153
3×300+1×150 34/18 2.4/1.8 0.5 3.1 69.1 12994 0.0601/0.124
3×400+1×185 53/30 2.6/2.0 0.5 3.3 76.9 16345 0.0470/0.0991
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
3×2.5+2×1.5 1/1 0.8/0.8 0.2 1.8 15.3 388 7.41/12.1
3×4+2×2.5 1/1 1.0/0.8 0.2 1.8 17.2 506 4.61/7.41
3×6+2×4 1/1 1.0/1.0 0.2 1.8 18.9 647 3.08/4.61
3×10+2×6 6/1 1.0/1.0 0.2 1.8 21.5 875 1.83/3.08
3×16+2×10 6/6 1.0/1.0 0.2 1.8 24.2 1194 1.15/1.83
3×25+2×16 6/6 1.2/1.0 0.2 1.8 27.7 1668 0.727/1.15
3×35+2×16 6/6 1.2/1.0 0.2 1.9 29.5 1994 0.524/1.15
3×50+2×25 6/6 1.4/1.2 0.2 2 34.9 2743 0.387/0.727
3×70+2×35 12/6 1.4/1.2 0.5 2.2 40 3996 0.268/0.524
3×95+2×50 15/6 1.6/1.4 0.5 2.4 46.2 5320 0.193/0.387
3×120+2×70 18/12 1.6/1.4 0.5 2.5 50.3 6585 0.153/0.268
3×150+2×70 18/12 1.8/1.4 0.5 2.6 53.5 7554 0.124/0.268
3×185+2×95 30/15 2.0/1.6 0.5 2.8 59.9 9538 0.0991/0.193
3×240+2×120 34/18 2.2/1.6 0.5 3 66.2 11948 0.0754/0.153
3×300+2×150 34/18 2.4/1.8 0.5 3.2 72.9 14632 0.0601/0.124
3×400+2×185 53/30 2.6/2.0 0.5 3.5 81.2 18414 0.0470/0.0991
No. of Cores and Nominal Cross Section Min. Number of Wires Nominal Insulation Thickness Nominal Steel Tape Thickness Nominal Sheath Thickness Approx. Overall Diameter Approx. Weight Max. D.C .Resistance of Conductor at 20℃
No.× mm² No. mm mm mm mm kg/km ohm/km
4×2.5+1×1.5 1/1 0.8/0.8 0.2 1.8 15.6 402 7.41/12.1
4×4+1×2.5 1/1 1.0/0.8 0.2 1.8 17.7 536 4.61/7.41
4×6+1×4 1/1 1.0/1.0 0.2 1.8 19.2 674 3.08/4.61
4×10+1×6 6/1 1.0/1.0 0.2 1.8 22.2 933 1.83/3.08
4×16+1×10 6/6 1.0/1.0 0.2 1.8 24.6 1262 1.15/1.83
4×25+1×16 6/6 1.2/1.0 0.2 1.8 28.5 1783 0.727/1.15
4×35+1×16 6/6 1.2/1.0 0.2 1.9 30.9 2217 0.524/1.15
4×50+1×25 6/6 1.4/1.2 0.2 2.1 36.5 3021 0.387/0.727
4×70+1×35 12/6 1.4/1.2 0.5 2.3 41.9 4405 0.268/0.524
4×95+1×50 15/6 1.6/1.4 0.5 2.4 48.2 5859 0.193/0.387
4×120+1×70 18/12 1.6/1.4 0.5 2.6 52.4 7181 0.153/0.268
4×150+1×70 18/12 1.8/1.4 0.5 2.7 57.1 8537 0.124/0.268
4×185+1×95 30/15 2.0/1.6 0.5 2.9 63 10575 0.0991/0.193
4×240+1×120 34/18 2.2/1.6 0.5 3.1 70 13342 0.0754/0.153
4×300+1×150 34/18 2.4/1.8 0.5 3.3 77.4 16455 0.0601/0.124
4×400+1×185 53/30 2.6/2.0 0.8 3.7 87.4 21557 0.0470/0.0991

FAQ

Which is NYBY cable?

NYBY is a PVC insulated and sheathed Copper conductor cable with galvanised steel tape armour for low voltage power applications. It is commonly used across European power distribution networks.

What is 0.6 1kV cable?

AA 0.6/1kV cable is a low-voltage electrical power cable. The rating indicates that the cable is designed to safely handle up to 0.6 kV (600 volts) between the conductor and the earth/ground, and up to 1 kV (1000 volts) between two phase conductors.This voltage capacity is standard for the vast majority of low-voltage distribution systems, main power supplies, and sub-mains in industrial, commercial, and large residential installations

What is the difference between STA and SWA cable?

Protection Type, STA cables provide only radial pressure protection, primarily resisting external compression and impact; SWA cables achieve dual protection against radial pressure and axial tensile forces, capable of withstanding multiple external stresses including compression, stretching, and impact simultaneously.

Technical support for NYBY Cable

For each project, the Qifan Cables technical team is available for support with specification, including determining the correct NYBY cable, the appropriate current carrying capacity, and the application of any de-rating factors. If you are in doubt as to which cable is the most appropriate for your project, we encourage you to get in touch and discuss it with one of our experts.


What is NYBY Cable Specification

The NYBY cable is suitable for static application installations in both internal and external dry and damp environments, including being buried with additional protection. The double layer of galvanised steel tape offers the cable a degree of mechanical protection but minimises the additional weight and overall diameter of the cable compared to the armour of flat or round steel wires.
Unlike the XLPE insulated N2XBY cable which has a maximum operating temperature of 90°C, the NYBY cable specifies a maximum of +70°C. Rated 0.6/1kV, it is manufactured in accordance with IEC 60502-1 and DIN VDE 0276-603.
The PVC sheathing provides protection from environmental conditions, being flame retardant and UV resistant.
The NYBY cable is available with green/yellow earth conductor in the multicore variants of cores and above, with the option of a reduced size earth in the 3 core cable.

What is the STA Armoured power cable?
STA (Steel Tape Armoured) 0.6/1KV power cables are low-voltage electrical cables designed for power transmission and distribution. They feature galvanized steel tape for mechanical protection, making them ideal for direct underground burial, outdoor installations, and environments requiring heavy-duty physical stress resistance.

Get In Touch

Let’s Build Something
Together.

No. 238, Zhenkang Road, Zhangyan Town,Jinshan District, Shanghai,China

Quick Link

Learn More About Us

About QIFAN
About QIFAN
We are a leading cable manufacturer in China with over 30 years of experience.
Customer Service
Customer Service
Exceptional Service– From First Contact to Long-Term Partnership
Quality Assurance
Quality Assurance
Advanced imported production lines; ISO 9001/14001/OHSAS 18001, TUV, VDE, UL, CE, SAA certified.