Industrial Cable

Home | Products | Cables by Industry | Industrial Cable

H05RN-F Multi core EI4 rubber insulated EM2 rubber sheath cable

H05RN-F

Application:

H05RN-F cable is suitable for the connection of all kinds of mobile electrical equipment with rated voltage not exceeding 300/500V. It can withstand large mechanical external force, and has certain outdoor weather resistance and oil pollution resistance.  

Standard:

  • Cable design: EN50525-2-21 
  • Conductor: EN 60228

Products Construction

  • Conductor – Plain flexible annealed class 5 copper
  •  Insulation – EPR rubber(EI4)
  •  Filler – Rubber(If need)
  •  Binder tape – Non-hygroscopic material tape(If need)
  •  Outer sheath – PCP or equivalent synthetic elastomer(EM2)

Cross Section:

  • 2C0.75~1mm2
  • 3C0.75~1mm2
  • 4C0.75~1mm2

Temperature characteristics:

  • Conductor operating temperature:-25℃~60℃               
  • Min. temperatrue laying condition: 0℃                 
  • Conductor short-circuit operating temperature (5s): 160℃

Electrical Characteristics:

  • Rated voltage: 300/500V
  • High voltage test:  2.0kV / 5min

Color:

  • Insulation: Yellow/Green, Black, Grey, Brown, Blue etc. According to customer requirements

Minimum Bending Radius

Flexible:7.5x Outer Ø       fixed:4x Outer Ø

Applicable Standards

EN50525-2-21
EN 60228

Optional

Anti-termite
Anti-rodent
Oil Resistance
UV Resistance

Technical Parameters

Technical characteristics of Rubber insulated cables-IEC60245.4

No. of CoreCross-section AreaMax. Wire Dia.Approx. Conductor Dia.Nominal Insulation ThicknessNominal Outer sheath thicknessApprrox. Cable Dia.Apporx. Cable WeightMax. D.C. Resistance at 20 ℃ 
Nosmm2mmmmmmmmmmkg/kmΩ/km
20.750.261.20.71.27.6069.426.00
210.261.340.71.27.8877.219.50
21.50.261.80.81.29.20104.013.30
22.50.262.370.91.310.94150.47.98
30.750.261.20.71.28.0084.726.00
310.261.340.71.28.3095.319.50
31.50.261.80.81.39.92135.013.30
32.50.262.370.91.311.58190.67.98
40.750.261.20.71.28.68101.726.00
410.261.340.71.29.01115.019.50
41.50.261.80.81.310.81163.513.30
42.50.262.370.91.412.87239.27.98
50.750.261.20.71.29.42118.826.00
510.261.340.71.310.00140.019.50
51.50.261.80.81.311.78192.813.30
52.50.262.370.91.414.06283.37.98
60.750.261.20.71.310.40141.426.00
610.261.340.71.310.82160.719.50
61.50.261.80.81.413.00227.913.30
62.50.262.370.91.415.31327.87.98
70.750.261.20.71.310.40154.526.00
710.261.340.71.310.82176.519.50
71.50.261.80.81.413.00251.213.30
72.50.262.370.91.415.31364.17.98
80.750.261.20.71.310.79169.826.00
810.261.340.71.311.23194.919.50
81.50.261.80.81.413.51277.713.30
82.50.262.370.91.516.14412.47.98
100.750.261.20.71.413.20215.226.00
1010.261.340.71.413.76246.619.50
101.50.261.80.81.516.60351.113.30
102.50.262.370.91.619.88518.67.98
120.750.261.20.71.413.60244.026.00
1210.261.340.71.414.18280.819.50
121.50.261.80.81.517.13401.213.30
122.50.262.370.91.620.53596.07.98
140.750.261.20.71.414.27274.626.00
1410.261.340.71.414.89317.119.50
141.50.261.80.81.518.00453.813.30
142.50.262.370.91.621.60676.87.98
160.750.261.20.71.415.02305.626.00
1610.261.340.71.515.88361.419.50
161.50.261.80.81.619.18515.813.30

FAQ

What is a HO5RN F cable?

The H05RN-F cable is a low voltage rubber sheathed power cable for flexible trailing applications. It is manufactured in accordance with VDE 0282 Part 4.

What is the difference between H05RN-F and H07RN-F?

H05RN-F and H07RN-F are both harmonized, flexible rubber-sheathed cables. The main difference is that H07RN-F is a heavy-duty cable designed for higher voltages and harsh, industrial environments, whereas H05RN-F is a lighter-duty, medium-durability cable intended for lower-voltage, portable equipment and indoor use.

What is the difference between H05RN F and H05RR F?

H05RR-F = light duty, for use in in households, kitchens & offices or for light utilities. H05RN-F = medium duty, for use in dry or damp areas, including temporary outdoor applications.nufactured in accordance with VDE 0282 Part 4.

What is H05RR F cable?

H07RN-F cables and SOOW cables may seem quite similar, but H07RN-F cables are better suited for flexible applications due to their higher flexibility, whereas SOOW cables are designed to withstand the pulling forces from equipment.

H05RR-F is a lightweight, harmonized, rubber insulated, flexible and jacketed multi-conductor European cord. They are recommended for use under conditions where there is minimal physical damage and only light mechanical stress.


What does H05RN F mean?

H05RN-F is a light duty flexible rubber cable used on hand tools and domestic appliances. * While every care has been taken to ensure specification sheets are correct and updated, these may differ or be amended without prior notice. Cable Construction. Class 5 flexible annealed copper.


Can H05RN-F cable be used outside?

It can be used indoor, outdoor, dry, wet and oily environments. It’s flame retardant and self extinguishes during fire. Not suitable for extremely mechanical stresses systems. Not suitable for direct burial installations.

Get In Touch

Let’s Build Something
Together.

No. 238, Zhenkang Road, Zhangyan Town,Jinshan District, Shanghai,China

Quick Link

Learn More About Us

About QIFAN
About QIFAN
We are a leading cable manufacturer in China with over 30 years of experience.
Customer Service
Customer Service
Exceptional Service– From First Contact to Long-Term Partnership
Quality Assurance
Quality Assurance
Advanced imported production lines; ISO 9001/14001/OHSAS 18001, TUV, VDE, UL, CE, SAA certified.