H05RN-F Multi core EI4 rubber insulated EM2 rubber sheath cable

H05RN-F cable is suitable for the connection of all kinds of mobile electrical equipment with rated voltage not exceeding 300/500V. It can withstand large mechanical external force, and has certain outdoor weather resistance and oil pollution resistance.
Flexible:7.5x Outer Ø fixed:4x Outer Ø
| No. of Core | Cross-section Area | Max. Wire Dia. | Approx. Conductor Dia. | Nominal Insulation Thickness | Nominal Outer sheath thickness | Apprrox. Cable Dia. | Apporx. Cable Weight | Max. D.C. Resistance at 20 ℃ |
| Nos | mm2 | mm | mm | mm | mm | mm | kg/km | Ω/km |
| 2 | 0.75 | 0.26 | 1.2 | 0.7 | 1.2 | 7.60 | 69.4 | 26.00 |
| 2 | 1 | 0.26 | 1.34 | 0.7 | 1.2 | 7.88 | 77.2 | 19.50 |
| 2 | 1.5 | 0.26 | 1.8 | 0.8 | 1.2 | 9.20 | 104.0 | 13.30 |
| 2 | 2.5 | 0.26 | 2.37 | 0.9 | 1.3 | 10.94 | 150.4 | 7.98 |
| 3 | 0.75 | 0.26 | 1.2 | 0.7 | 1.2 | 8.00 | 84.7 | 26.00 |
| 3 | 1 | 0.26 | 1.34 | 0.7 | 1.2 | 8.30 | 95.3 | 19.50 |
| 3 | 1.5 | 0.26 | 1.8 | 0.8 | 1.3 | 9.92 | 135.0 | 13.30 |
| 3 | 2.5 | 0.26 | 2.37 | 0.9 | 1.3 | 11.58 | 190.6 | 7.98 |
| 4 | 0.75 | 0.26 | 1.2 | 0.7 | 1.2 | 8.68 | 101.7 | 26.00 |
| 4 | 1 | 0.26 | 1.34 | 0.7 | 1.2 | 9.01 | 115.0 | 19.50 |
| 4 | 1.5 | 0.26 | 1.8 | 0.8 | 1.3 | 10.81 | 163.5 | 13.30 |
| 4 | 2.5 | 0.26 | 2.37 | 0.9 | 1.4 | 12.87 | 239.2 | 7.98 |
| 5 | 0.75 | 0.26 | 1.2 | 0.7 | 1.2 | 9.42 | 118.8 | 26.00 |
| 5 | 1 | 0.26 | 1.34 | 0.7 | 1.3 | 10.00 | 140.0 | 19.50 |
| 5 | 1.5 | 0.26 | 1.8 | 0.8 | 1.3 | 11.78 | 192.8 | 13.30 |
| 5 | 2.5 | 0.26 | 2.37 | 0.9 | 1.4 | 14.06 | 283.3 | 7.98 |
| 6 | 0.75 | 0.26 | 1.2 | 0.7 | 1.3 | 10.40 | 141.4 | 26.00 |
| 6 | 1 | 0.26 | 1.34 | 0.7 | 1.3 | 10.82 | 160.7 | 19.50 |
| 6 | 1.5 | 0.26 | 1.8 | 0.8 | 1.4 | 13.00 | 227.9 | 13.30 |
| 6 | 2.5 | 0.26 | 2.37 | 0.9 | 1.4 | 15.31 | 327.8 | 7.98 |
| 7 | 0.75 | 0.26 | 1.2 | 0.7 | 1.3 | 10.40 | 154.5 | 26.00 |
| 7 | 1 | 0.26 | 1.34 | 0.7 | 1.3 | 10.82 | 176.5 | 19.50 |
| 7 | 1.5 | 0.26 | 1.8 | 0.8 | 1.4 | 13.00 | 251.2 | 13.30 |
| 7 | 2.5 | 0.26 | 2.37 | 0.9 | 1.4 | 15.31 | 364.1 | 7.98 |
| 8 | 0.75 | 0.26 | 1.2 | 0.7 | 1.3 | 10.79 | 169.8 | 26.00 |
| 8 | 1 | 0.26 | 1.34 | 0.7 | 1.3 | 11.23 | 194.9 | 19.50 |
| 8 | 1.5 | 0.26 | 1.8 | 0.8 | 1.4 | 13.51 | 277.7 | 13.30 |
| 8 | 2.5 | 0.26 | 2.37 | 0.9 | 1.5 | 16.14 | 412.4 | 7.98 |
| 10 | 0.75 | 0.26 | 1.2 | 0.7 | 1.4 | 13.20 | 215.2 | 26.00 |
| 10 | 1 | 0.26 | 1.34 | 0.7 | 1.4 | 13.76 | 246.6 | 19.50 |
| 10 | 1.5 | 0.26 | 1.8 | 0.8 | 1.5 | 16.60 | 351.1 | 13.30 |
| 10 | 2.5 | 0.26 | 2.37 | 0.9 | 1.6 | 19.88 | 518.6 | 7.98 |
| 12 | 0.75 | 0.26 | 1.2 | 0.7 | 1.4 | 13.60 | 244.0 | 26.00 |
| 12 | 1 | 0.26 | 1.34 | 0.7 | 1.4 | 14.18 | 280.8 | 19.50 |
| 12 | 1.5 | 0.26 | 1.8 | 0.8 | 1.5 | 17.13 | 401.2 | 13.30 |
| 12 | 2.5 | 0.26 | 2.37 | 0.9 | 1.6 | 20.53 | 596.0 | 7.98 |
| 14 | 0.75 | 0.26 | 1.2 | 0.7 | 1.4 | 14.27 | 274.6 | 26.00 |
| 14 | 1 | 0.26 | 1.34 | 0.7 | 1.4 | 14.89 | 317.1 | 19.50 |
| 14 | 1.5 | 0.26 | 1.8 | 0.8 | 1.5 | 18.00 | 453.8 | 13.30 |
| 14 | 2.5 | 0.26 | 2.37 | 0.9 | 1.6 | 21.60 | 676.8 | 7.98 |
| 16 | 0.75 | 0.26 | 1.2 | 0.7 | 1.4 | 15.02 | 305.6 | 26.00 |
| 16 | 1 | 0.26 | 1.34 | 0.7 | 1.5 | 15.88 | 361.4 | 19.50 |
| 16 | 1.5 | 0.26 | 1.8 | 0.8 | 1.6 | 19.18 | 515.8 | 13.30 |
The H05RN-F cable is a low voltage rubber sheathed power cable for flexible trailing applications. It is manufactured in accordance with VDE 0282 Part 4.
H05RN-F and H07RN-F are both harmonized, flexible rubber-sheathed cables. The main difference is that H07RN-F is a heavy-duty cable designed for higher voltages and harsh, industrial environments, whereas H05RN-F is a lighter-duty, medium-durability cable intended for lower-voltage, portable equipment and indoor use.
H05RR-F = light duty, for use in in households, kitchens & offices or for light utilities. H05RN-F = medium duty, for use in dry or damp areas, including temporary outdoor applications.nufactured in accordance with VDE 0282 Part 4.
H05RR-F is a lightweight, harmonized, rubber insulated, flexible and jacketed multi-conductor European cord. They are recommended for use under conditions where there is minimal physical damage and only light mechanical stress.
H05RN-F is a light duty flexible rubber cable used on hand tools and domestic appliances. * While every care has been taken to ensure specification sheets are correct and updated, these may differ or be amended without prior notice. Cable Construction. Class 5 flexible annealed copper.
It can be used indoor, outdoor, dry, wet and oily environments. It’s flame retardant and self extinguishes during fire. Not suitable for extremely mechanical stresses systems. Not suitable for direct burial installations.
Get In Touch
Our team of multilingual sales professionals and technical specialists are on hand to support you with your cable projects, from specification through to installation. Please use the contact details below to get in touch.
Quick Link